AS 1670.4

EWIS Block Plans

An EWIS block plan documents the Emergency Warning and Intercommunication System in a building. It shows speaker zones, warden intercom phone (WIP) locations, alert/evacuate zone sequences, and the relationship between detection zones and EWIS response — essential for emergency wardens and fire brigade operations.

What is an EWIS block plan?

An EWIS block plan is a schematic showing the layout and zoning of a building's Emergency Warning and Intercommunication System. It documents speaker zones, WIP locations, the alert/evacuate sequence and how the system interfaces with fire detection. It enables wardens and fire crews to understand and manage evacuation communications.

Why do you need one?

AS 1670.4 requires EWIS documentation that enables system operation and testing. Buildings with EWIS must have clear documentation of zone layout and evacuation sequences. Fire brigades use this documentation when they take control of the system during an emergency.

What AS 1670.4 requires

The block plan should show: speaker zone boundaries and identification, WIP locations and zone allocation, alert/evacuate sequencing (which zones alert vs. evacuate on each trigger), interface with fire detection zones, manual override controls, and any staged evacuation logic.

Common problems we solve

EWIS documentation is often the most neglected of all fire safety documentation. Common issues include: no EWIS block plan at all, plans that don't reflect current zone programming, missing cause-and-effect documentation for alert/evacuate sequences, and plans not updated after tenancy changes or floor reconfigurations.

Frequently Asked Questions

What is the difference between alert and evacuate?

In a staged evacuation system, "alert" notifies occupants of a potential emergency (beep tone), while "evacuate" gives the instruction to leave (whoop tone + voice message). The block plan documents which zones receive which signal in each scenario.

Do you document the cause-and-effect for EWIS?

Yes. We document the programmed alert/evacuate sequences — which detection zone triggers which EWIS response and in what order.

Is EWIS documentation needed for the Annual Fire Safety Statement?

Yes. If your building has an EWIS, its maintenance and documentation are covered by the fire safety schedule and must be current for the AFSS.

Need compliant fire documentation?

Tell us about your building and our engineers will get back to you fast with a clear, no-obligation quote.

Get Free Quote

Fire Block Plans Australia — Engineering-Led Compliance Documentation

Sydney Block Plan provides FPAS engineer-prepared fire block plans, evacuation diagrams and baseline data services across Australia. Our documentation is prepared by qualified fire protection engineers — not generic drafters.

Our Fire Compliance Services

We prepare standards-compliant documentation for every fire protection system in your building:

Industries We Serve

From strata buildings to hospitals, we document the buildings that keep Australia running:

Why Choose Sydney Block Plan

Most block plan providers are drafters. We are fire protection engineers — and that difference shows in every document we deliver.

Service Locations

We provide fire block plan services across Australia including Sydney, Parramatta, Penrith, Liverpool, Campbelltown, Central Coast, Newcastle, Wollongong, Melbourne, Brisbane, Perth, Adelaide, Canberra, Hobart and Darwin.

Contact Us

Phone: 0433 465 095

Email: info@sydneyblockplan.com.au

Address: Level 1, Office 1, 310 Forest Road, Hurstville NSW 2221

Hours: Monday–Friday 8:00am – 6:00pm

Connect With Us

Facebook | LinkedIn